Physical Properties Print Version
Flooring Radiant Panel ASTM E648; NBSIR 75-950; NFPA 253, Critical Radiant Flux 0.73 W/cm², Class I
Residual Indentation Residual Indentation DIN 51955 25 hrs.) <.15mm (.0059")
Bending Resistance 1cm mandrel DIN 51949 no cracking
Abrasive Wear EMPA .05mm
Resistance to Light Fading ISO 6 7 good (indoor use)
Point load resistance DIN 5`955 >.15mm (.0059")
National Floor Safety Institute Test www.nfsi.org High Traction >0.60 Certified
Static Coefficient of Friction GPHSZ 032 dynamometer pull method dry surface 0.7
wet surface 0.6
Shore Hardness A 75
Static Load Limit DIN 16961.2 <350 lbs/in²
Thermal conductivity DIN 52612 (Heat transfer coefficient) .35K/cal/h/ °C
(172.5Kcal/m² °C)
Dimensional Stability DIN 51962 directional and cross directional shrinkage <.1%
Rolling castor chair test DIN 54324 passes
Chemical Resistance Very good to most diluted acids, alkalis and common detergents.Some solvents can swell or dissolve vinyl.(Request detailed information from manufacturer).
Not resistant to rubber (yellowing from certain antioxidants, oil based grease, tar based asphalt, lipstick cause permanent staining or discoloration.
Safefloor Guard meets or exceeds requirements of Federal Specification LF-475A and SST 312b for dimensional stability, flexibility, resistance to reagents and residual indentation.